About seller
Walking is recommended for patients with peripheral arterial disease (PAD). It has been shown that patients with PAD present sharper increases in blood pressure (BP) and heart rate (HR) during maximal walking when compared with healthy subjects. Additionally, women with PAD present a worse physiological profile, and it is possible that they may present higher cardiovascular load during and after a bout of maximal walking than men. Thus, the objective of this study was to compare cardiovascular and autonomic responses during and after maximal walking between men and women with PAD and intermittent claudication (IC). Forty patients with PAD and IC (20 men and 20 women) underwent, in random order, 2 sessions control (standing on treadmill) and exercise (maximal treadmill walking test with Gardner's protocol). During the exercise, HR and BP were measured. Before and after the sessions, cardiovascular variables (BP HR, cardiac output, peripheral vascular resistance, and stroke volume) and autonomic modulation (HR and BP variabilities and baroreflex sensitivity) were assessed. TTNPB nmr In addition, an ambulatory BP monitoring was recorded after each session. Men and women presented similar maximal walking capacity. During the walking test, HR and systolic BP increased similarly in men and women. After the maximal walking, cardiovascular and autonomic responses did not differ between the genders. In addition, postintervention ambulatory BP parameters were also similar in men and women. Therefore, in men and women, maximal walking similarly reduced clinic systolic BP and stroke volume, and increased HR and total power of HR variability during the recovery period. Men and women with PAD and IC present similar cardiovascular and autonomic responses during and after maximal walking.Men and women with PAD and IC present similar cardiovascular and autonomic responses during and after maximal walking. The ability to salvage the mangled lower extremity is both technically challenging and time consuming. It requires the collaborative efforts among multiple surgical specialties in addition to comprehensive post-traumatic wound follow-up. Our institution has integrated a dynamic effort among these specialists in the planning and facilitating a successful limb salvage program with creation of a mangled extremity algorithm. An integral part in this process is the vascular inflow to prepare coverage for large tissue defects lacking adequate recipient targets. Utilization of long saphenous arteriovenous (AV) loop has been cited with minimal data available using larger inflow vessels in the acute trauma setting. We performed a retrospective review and describe our early experience using our protocol with AV loop creation with free flap reconstruction to salvage traumatic leg injuries. Using the data, we sought to develop a mangled extremity protocol for trauma centers to guide mangled limb salvage. Since June 2ol to guide limb salvage has proven successful in our early experience. Long-term data need to be complied to assess patency of the free flap transfer and quality of life outcomes.Although a small patient cohort, utilization of long saphenous vein AV loop is successful as a bridge to free flap transfer for isolated mangled lower extremities. Development and incorporation of our mangled extremity protocol to guide limb salvage has proven successful in our early experience. Long-term data need to be complied to assess patency of the free flap transfer and quality of life outcomes. Shaggy aorta (SA) depicts the severe aortic surface degeneration, extremely friable, and likely to cause spontaneous peripheral and visceral embolization or during catheterization, aortic manipulation, surgery, or minimally invasive procedures. This study aims to provide the most accurate and up-to-date information on this disease. Potentially eligible studies to be included were identified by searching the following databases CENTRAL Library, ClinicalTrials.gov, MEDLINE, and CINAHL, using a combination of subject headings and text words to identify relevant studies (Shaggy aorta) OR (aortic embolization) OR (aortic embolism) OR (aortic thrombus) OR (aortic plaque). From a total of 29,111 abstracts, and after applying inclusion and exclusion criteria, we considered 60 studies for inclusion in this review. Appropriate measurement and assessment of the aortic wall are pivotal in the modern era, in particular when percutaneous procedures are performed, as SA has been identified as an independent risk factor for spinal cord injury, mesenteric embolization, and cerebral infarction after endovascular aortic repair. Furthermore, SA increases the rate of cerebral complications during transcatheter aortic valve implantation. In conclusion, prompt diagnosis of SA syndrome and appropriate guidelines on the management of these conditions may help physicians to better assess the patient risk and to minimize the dreadful-related complications.In conclusion, prompt diagnosis of SA syndrome and appropriate guidelines on the management of these conditions may help physicians to better assess the patient risk and to minimize the dreadful-related complications. The aim of this study is to compare early and late results of an expanded polytetrafluoroethylene (ePTFE-Gore TAG®, group A) mesh structured endograft versus a Dacron one (Relay Plus® Bolton, group B) in thoracic endovascular aneurysm repair (TEVAR). A prospective database was used to extract information from anonymous patients who underwent TEVAR for descending thoracic aortic aneurysms (DTAAs) between February 2005 and February 2019 at 3 referral university hospitals. Cases treated by means of ePTFE endograft (Gore TAG, group A) and Dacron graft (Relay Plus Bolton, group B) in elective and urgent settings were included. Early and late outcomes were compared. A total of 129 consecutive patients were included (115 men and 14 women). ePTFE-Gore TAG® and Dacron-Relay Plus® Bolton were used in 56 (43.4%) and 73 (56.5%) patients, respectively. Preoperative characteristics of patients were similar. Technical success was 100%. Urgent procedures were 22.4%. Mean aortic coverage and partial debranching were 217.