tankertiger16
tankertiger16
0 active listings
Last online 1 year ago
Registered for 1+ year
Isuikwuato, Kaduna, Nigeria
708394Show Number
Send message All seller items (0) www.selleckchem.com/products/mln-4924.html
About seller
Peripheral nerve interfaces (PNIs) allow us to extract motor, sensory and autonomic information from the nervous system and use it as control signals in neuroprosthetic and neuromodulation systems. Recent efforts have aimed to improve the recording selectivity of PNIs, including by using spatiotemporal patterns from multi-contact nerve cuff electrodes as input to a convolutional neural network (CNN). Before such a methodology can be translated to humans, its performance in chronic implantation scenarios must be evaluated. We investigated the performance of a CNN-based selective recording approach in the presence of encapsulation tissue, a common immune response to the implantation of a neural interface. This factor was simulated using anatomically accurate computational models of a rat sciatic nerve and nerve cuff electrode. Performance over time was examined in three conditions training the CNN at baseline only, supervised retraining with explicitly labeled data at periodic intervals, and a semi-supervised self-learning approach. The periodic recalibration approach demonstrated the best results, with an average F1-score of 0.96 ± 0.04, 0.89 ± 0.08, and 0.80 ± 0.08 for SNRs of -5 dB, -10 dB, and -15 dB, respectively, across all time points. Thus, the periodic recalibration approach may be an effective solution to compensate for changes in signal recordings seen over time as a result of encapsulation tissue. The self-learning approach, in which a network is retrained periodically using predicted labels, generally showed degradation in classification performance over time, even as the frequency of training was increased, attributed to an eventual accumulation of mislabeled training data.The phase-amplitude coupling in EEG signal of different frequencies is considered as a useful biomarker in delineating epileptogenic tissues, but some physiological processes can also generate phase-amplitude coupling pattern, such as memory process. Current analysis on cross-frequency coupling (CFC) feature is mostly based on extracting the strength of coupling but not coupling patterns in frequency-frequency domain. In this paper, we proposed a method for identifying epileptogenic tissue using convolutional neural networks (CNN) based on CFC pattern. Stereo-electroencephalograph (SEEG) from six patients with intractable epilepsy were used in this analysis. First, modulation indexes (MIs) were calculated using a moving window for each channel across seizures. Then those MIs were marked as inside epileptogenic zone (EZ) or outside EZ based on the surgical resection area. CNN was trained by those two-dimensional coupling patterns and tested by leave-one-out method. The receiver operating characteristics (ROC) curve was further generated. The results showed that average area-under-curve (AUC) performance reached 0.88. The sensitivity was 0.81, and the specificity was 0.79. Those results suggest that the CFC pattern can be used to identify SEEG channels in the epileptogenic region using the CNN.Clinical Relevance- This method has the potential to be used as an analytical tool for neurologists to identify epileptogenic brain tissues.To meet the dimensional requirements for bioelectronic medicine, new packaging solutions are needed that could enable small, light-weight and flexible implants. For protecting the implantable electronics against biofluids, recently various atomic layer deposited (ALD) coatings have been proposed with high barrier properties. Before implantation, however, the protective coating should be evaluated for any defects which could otherwise lead to leakage and device failure. learn more In these cases, the conventional helium leak test method can no longer be used due to the millimeter size of the implant. Therefore, an in-situ sensing platform is needed that could evaluate the coating and justify the implantation of the final device. In this work, we explore the possibility of using the CMOS bulk for such a platform. Towards this aim, as a proof of concept, test chips were made in a standard 6-metal 0.18 µm CMOS process and for the connection to the bulk, a p+ diffusion was used. A group of samples was then coated with an ALD multilayer. For coating evaluation, off-chip DC current leakage and impedance measurements were carried out in saline between the CMOS bulk and a platinum reference electrode. Results were compared between non-coated and coated chips that clearly demonstrated the potential of using the bulk as a sensing platform for coating evaluations. This novel approach could pave the way towards an all integrated in-situ hermeticity test, currently missing in mm-size implants.Many advances have been made with imaging of implanted neural devices; however, the ability to image whole nerve samples remains limited. Further, few imaging modalities are well suited for visualizing both whole devices in vivo and individual microelectrodes within a nerve. In this study, we used micro-computed tomography (micro-CT) to evaluate Wireless Floating Microelectrode Arrays (WMFAs) implanted in rat sciatic nerve at the level of whole devices and individual electrodes. WFMAs were also used to track selective recruitment of plantar flexion and dorsiflexion of the rear paw, which was achieved by each implanted device (n=6) during chronic implantation. Evoked limb motion was correlated to end-of-study assessments using micro-CT to visualize electrode locations within the fascicular structure of the sciatic nerve. Results of this study show that micro-CT imaging can provide valuable assessments of microelectrode arrays implanted in peripheral nerves for both whole devices visualized in vivo and individual electrodes visualized in whole nerve tissue samples.Clinical relevance- This work informs the use of micro-computed tomography as a tool for correlating neural device performance with physical attributes of the implant location.High Frequency Oscillations (HFOs, 200-600 Hz) are recognized as a biomarker of epileptogenic brain areas. This work aims at designing novel microelectrodes in order to optimize the recording and further detection of HFOs in brain (intracerebral electroencephalography, iEEG). The quality of the recorded iEEG signals is highly dependent on the electrode contact impedance, which is determined by the characteristics of the recording electrode (geometry, position, material). These properties are essential for the observability of HFOs. In this study, a previously published hippocampal neural network model is used for the simulation of interictal HFOs. An additional microelectrode model layer is implemented in order to simulate the impact of using different types and characteristics of microelectrodes on the recorded HFOs. Results indicate that a small layer PEDOT/PSS and PEDOT/CNT on microelectrodes can effectively decrease their impedance resulting in the increase of HFOs observability. This model-based study can lead to the actual design of new electrodes that will ultimately contribute to improved diagnosis prior to invasive therapies.

tankertiger16's listings

User has no active listings
Start selling your products faster and free Create Acount With Ease
Non-logged user
Hello wave
Welcome! Sign in or register