About seller
Tranexamic acid (TXA) has shown to reduce perioperative blood loss after bilateral total knee arthroplasty (TKA). But dosage and schedule of administration are not clear in literature. This study was aimed to compare prospectively blood loss and transfusion requirement in bilateral TKA with 3-dose regimen versus a single intra-operative dose of intravenous TXA. This prospective non-randomised controlled trial included 25 patients undergoing bilateral simultaneous TKA who received three doses of 1 g intravenous TXA (group 1). First dose was given prior to deflation of the tourniquet, followed by two more doses 6 h apart. The control group included 25 matched patients (group 2) receiving a single dose of 1 g intravenous TXA just prior to deflation of the tourniquet. Mean drop in haemoglobin was less in group 1 as compared to group 2, but this difference was not statistically significant (2.51 vs 2.93g/dL, = 0.210). Similarly mean drop in haematocrit was more in group 2 as compared to group 1, though it was not statistically significant (9.34 vs. 9.18, = 0.868). The need for blood transfusions was more in group 2 compared to group 1, but this difference was not statistically significant ( = 0.601). Higher frequency of ecchymosis around the surgical site was noted in group 2 as compared to group 1, for which prophylactic low-molecular-weight heparin had to be stopped post-operatively, but this difference was not statistically significant ( = 0.065). The study has failed to show any significant beneficial effect of three doses of TXA in TKA as compared to a single dose. Though a trend towards reduction in mean haemoglobin drop and decreased need for stopping LMWH in post-operative period was seen, the results were not statistically significant. II, prospective non-randomised controlled trial.II, prospective non-randomised controlled trial. Hip hemiarthroplasty (HA) is a standard surgical procedure for elderly patients with displaced fracture of the femoral neck, where dislocation is a possible complication. This study is a systematic review on the risk factors of implant dislocation in patients with femoral neck fracture following hip hemiarthroplasty (HA), and evaluates the methodological quality of the included studies. Studies on risk factor assessment of dislocation following hip HA were sourced from EMBASE, Ovid, PubMed and ScienceDirect databases. The quality of included studies was evaluated using an improved quality evaluation method combined with a best-evidence synthesis method. A total of 130,127 patients were involved in 17 observational studies included in this systematic review, with a dislocation rate that ranged between 0.76 and 12.2% (overall incidence was 4-5% by meta-analysis). According to the applied quality evaluation criteria, eight studies were considered to be of high quality, six to be of medium quality, and threrisk factors is lacking and more methodologically rigorous studies are required to increase the confidence of recommendations. The literature around use of Large Diameter Heads (LDH) is abundantly available for revision Total Hip Arthroplasty (THA) but is lacking for primary uncomplicated THA. This systematic review was undertaken to synthesize data around primary THA involving LDH and analyze the associated complications (dislocation, volumetric wear, implant survivorship and functional score) along with reported effects on range of motion (ROM), patient reported outcomes and impingement rate/groin pain. A PRISMA compliant systematic review was done using extensive search in PubMed database, along with offline search looking for the literature published in English language between 2008 and 2018. The articles providing data on the use of large diameter heads (LDH) (36mm or larger) on various bearing surfaces were collected. This included robust national joint registries of different countries. Narrative approach to data synthesis was used. A total of 23 papers met our inclusion criteria, including six national joint registries. Selleck SGI-1776 It was observed that LDH had significantly low dislocation rates, excellent implant survival rate as per Kaplan-Meier survivorship (> 90% at five years). Surgical approaches, except Minimally Invasive Surgery (MIS), did not increase any risk of dislocation as long as it was meticulously repaired. There was no significant improvement in any functional scores or improved ROM. LDH of 32-36mm are now commonly used in primary THA and is accepted as a popular size. The beneficial effects of a large head size are negated beyond 38mm. The most favored size for LDH THA, therefore, is 36mm contrary to the older literature favoring 28mm.LDH of 32-36 mm are now commonly used in primary THA and is accepted as a popular size. The beneficial effects of a large head size are negated beyond 38 mm. The most favored size for LDH THA, therefore, is 36 mm contrary to the older literature favoring 28 mm. There is a lack of consensus on the optimal method of performing primary hip arthroplasty in obese patients and limited evidence. This article presents a series of considerations based on the authors' experiences as well as a review of the literature. In the preoperative phase, an informed consent process is recommended. Weight loss is recommended according to NHS England guidelines, and body habitus should be taken into account. When templating, steps are taken to avoid overestimating the implant size. During the surgical procedure, specialist bariatric equipment is utilised bariatric beds, extra supports, hover mattresses, longer scalpels, diathermy, cell saver and minimally invasive surgery equipment. Communication with the anaesthetist and surgical team to anticipate is vital. Intraoperative sizing and imaging, if required, should be considered. Pneumatic foot pumps are preferable for VTE prophylaxis. Regional anaesthesia is preferred due to technical difficulty. IV antibiotics and tranexamic acid are recommended. The anterior and posterior surgical approaches are most frequently used; we advocate posterior. Incisions are extensile and a higher offset is considered intraoperatively, as well as dual mobility and constrained liners to reduce dislocation risk. When closing the wound, Charnely button and sponge should be considered as well as negative pressure wound dressings (iNPWTd) and drains. Postoperatively, difficult extubation should be anticipated with ITU/HDU beds available. Epidural anaesthetics for postoperative pain management require higher nursing vigilance. Chemical prophylaxis is recommended. Despite being technically more difficult with higher risks, functional outcomes are comparable with patients with a normal BMI.Despite being technically more difficult with higher risks, functional outcomes are comparable with patients with a normal BMI.