About seller
Taking into account the impact of shipment method of biosamples is necessary for obtaining high-quality biological samples in biobanking and laboratory research. The impact of liquid nitrogen, dry ice and cold accumulators on the quality of biological markers was considered, as well as recommendations to reduce the impact of these methods of shipment. The liquid nitrogen provides the best preservation of samples, however, dry ice is used much more often during their transportation. When transporting certain types of cells using dry ice, there is the way to use CryoStor CS1 and Cell Banker 1 cryoprotectors. The dry ice has a significant effect on both the pH of liquid biological samples and the coagulological parameters of plasma samples. The penetration of CO2 into the sample leads to changes in the parameters of PTT and APPT, as well as to decrease the protein C and fibrinogen level under certain conditions. Serum and plasma samples exposed to dry ice for more than 16 hours should be thawed open at room temperature, or instead of it should be kept at -80 °C for 24 hours to avoid changes in coagulation parameters, The use of cold accumulators is unacceptable for long-term shipment of serum and plasma containing unstable biomarkers because of insufficiently low temperature (increase over time to -25 °C and above). Degrasyn solubility dmso Besides, metal pellets can be used as cold storage batteries at low temperatures (up to -80 ° C), but they are not as effective as dry ice, since it is able to hold the required temperature for much longer.Immunochromatographic test systems known to foreign laboratory diagnostic experts as lateral flow immunoassay (LFIA) are simplified tape formats of modern biosensors. For 60 years, they have been widely used for the rapid detection of target molecules (ligands) in biosubstrates and the diagnosis of many diseases and conditions. The growing popularity of these test systems for providing medical care or diagnostics in developing countries, medical facilities, in emergency situations, as well as for individual home use by patients while monitoring their health are the main factors contributing to the continuous development and improvement of these methods, the emergence of a new generation of formats. The attractiveness and popularity of these fast, easy-to-use, inexpensive and portable diagnostic tools is associated primarily with their high analytical sensitivity and specificity, as well as the ease of interpretation of the results. These qualities have passed the test of time, and today LFIA test systems are fully consistent with the modern world concept of «point-of-care testing», finding wide application not only in medicine, but also in ecology, veterinary medicine, and agriculture. This review will highlight the modern principles of designing the most widely used formats of immunochromatographic test systems for clinical laboratory diagnostics, summarize the main advantages and disadvantages of the method, as well as current achievements and prospects of LFIA technology. Modern innovations aimed at improving the analytical characteristics of LFIA technology are interesting, promising and can bring additional benefits to immunochromatographic platforms that have gained popularity and attractiveness for six decades.Comparative analysis of the impact of blood collection systems on the results of routine coagulation tests. The aim of this study was to conduct comparative analysis of the effects of blood collection systems on the results of routine coagulation tests. The study involved practically healthy women over 18 years of age female (n=30). Inclusion criteria practically healthy individuals. Exclusion criteria taking non-steroidal anti-inflammatory drugs, or oral contraceptives. Blood collection was carried out in the following systems 1 system-Vacuette Premium,2 system- Improvacuter, 3 system- BD Vacutainer® Plus. Before and after centrifugation, visual assessment of tubes was performed.No signs for the presence of clots, hemolysis, or insufficient filling was observed. In each sample we measured prothrombin time (PV, sec), activated partial thromboplastin time (APTT, sec), and fibrinogen (F, g/l) by clotting method on the automatic coagulometer «Sta Compact» («Diagnostica Stago», France). The results of laboratory analyses were processed using parametric and non - parametric statistics using The Statistica 12.0 software. At the preanalytical laboratory stage, there were no differences when using systems for blood sampling the clots and hemolysis were not detected in the samples, the level of filling of the sistems was sufficient. Comparative analysis revealed small, though statistically significant, differences for PT when comparing Improvacuter wiht Vacuette Premium or BD Vacutainer®; APPT when comparing Improvacuter wiht Vacuette Premium. No differences were observed for Fg levels. Our results support the data available in the literature on the effects of blood-taking systems on hemostasis , which should be taken into account when purchasing blood collection systems.To assess the change in the functional state of the proximal renal tubule epithelium in patients with dyslipidemia on the background of obesity, by determining the concentration in the urine of the examined level of cystatin C and the degree of activity of the renal organ-specific enzymes neutral α-glucosidase (NAG) and L-alaninaminopeptidase (laap) during simvastatin therapy at a daily dose of 20 mg for 6 months. The study involved 88 people who were divided into three groups control, comparison and main. The control group is a group of practically healthy individuals 30 people, average age 20.67 ± 0.18 years, body mass index (BMI) 21.36 ± 0.4 kg/m2. Comparison group (obese) 27 people, average age 22.38 ± 0.76 years, BMI 31.48 ± 0.56 kg / m2. Patients of the main group were divided into 2 subgroups. The first main subgroup of persons with chronic heart failure stage I (CHF I) without type 2 diabetes mellitus (DM 2)) - 15 observed average age 56.8 ± 1.8 years, BMI 30.28 ± 1.11 kg / m2. The second main subgroue at a daily dosage of 20 mg does not impair glomerular function in the form of reduced glomerular filtration rate (GFR). Cystatin C levels are higher in obese individuals without heart failure and significantly higher in those with asymptomatic heart failure. When treating dyslipidemia with simvastatin at a dose of 20 mg / day, there is a decrease in the activity of NAG and laap in patients with CHF I without DM2. In the result of lipid-lowering therapy with simvastatin in a daily dosage of 20 mg in patients with CHF I+D2M there is increased activity of NAG while reducing the concentration of the LAAP, which may be due to degeneration of the proximal tubular epithelium, amid additional load on a partially renal route of metabolism of simvastatin.