riddlekitten44
riddlekitten44
0 active listings
Last online 1 year ago
Registered for 1+ year
Ugwunagbo, Bauchi, Nigeria
708394Show Number
Send message All seller items (0) www.selleckchem.com/products/ly3039478.html
About seller
In this study, we designed a dual colorimetric and fluorometric sensor by using nitrogen and phosphor doped carbon dots (N, P-CDs) and Ag nanoprisms (AgNPrs) to detect 6-mercaptopurine (6-MP). For this purpose, we applied the AgNPrs/I- mixture to establish a shape transformation based colorimetric method for the detection of 6-MP. The assay mechanism of colorimetric method was based on etching and protecting effect of I- and 6-MP on the AgNPrs. In the presence of I-, as an etching agent, the solution color altered from blue to purple and the position of AgNPrs' local surface plasmon resonance (LSPR) peak shifted to the blue wavelengths. This phenomenon was assigned to the morphological change of AgNPrs. In the presence of 6-MP, AgNPrs were protected from etching by I-, so the LSPR peak position and solution color of AgNPrs remained unchangeable. Furthermore, the fluorescence intensity of N, P-CDs decreased with adding AgNPrs/I- due to the spectral overlap between etched AgNPrs and N, P-CDs. The CDs' quenched fluorescence was restored in the presence of 6-MP, as a result of the protecting effect of 6-MP on the AgNPrs. These facts have been applied to develop a dual sensor for the determination of 6-MP at the range of 10-500 nM and 30-500 nM by colorimetric and fluorometric detection methods. The detection limits were obtained 10 and 4 nM for fluorometric and colorimetric methods, respectively. Selleckchem Crenigacestat The developed sensor was utilized for dual signal analysis of 6-MP in human serum samples with satisfactory results.A rapid and simple fluorescence probe based on CeO2 quantum dots (QDs) was developed for highly selective and ultrasensitive direct determination of 4-nitrophenol (4-NP). CeO2 QDs were prepared using the sol-gelmethod with the precursor of Ce(NO3)3·6H2O as a cerium source. The products were characterized through high-resolution electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy. The fluorescent probe based on CeO2 QDs exhibited a broad linear response to the concentration of 4-NP in the range of 0.005-75.00 μM and provided a low detection limit of 1.50 nM. The fluorescence of CeO2 QDs was quenched by 4-NP through the fluorescence resonance energy transfer mechanism owing to the well overlaps between the fluorescence emission spectrum of CeO2 QDs with the ultraviolet absorption spectrum of 4-NP. This result was confirmed by the time-resolved fluorescence spectra and the evaluation of the interaction distance between CeO2 QDs and 4-NP. The prepared CeO2 QDs are successfully applied to the determination of 4-NP in real water samples, where the spiked recoveries range from 98.2% to 102.4%.In this paper, a series of novel phenylenediamine-fluoroboron pyrrole fluorescent derivatives were prepared which have distinct responsiveness under different hydrogen ion concentration (pH) conditions. It is noticed that the products showed excellent fluorescence properties in different solvents, especially in tetrahydrofuran and dichloromethane, with the most prominent fluorescence intensity, while the fluorescence in methanol, acetonitrile, and dimethyl sulfoxide was weaker. Responsiveness under different hydrogen ion concentration conditions in aqueous solutions were also observed, where the fluorescence intensity is quenching when the pH is 4.0. With regard to cells imaging investigation, the products showed the prominent fluorescence in HeLa cells. Further acidic cell imaging results showed that under acidic conditions made of formic acid or acetic acid, the intracellular fluorescence of the compounds was clustered around the cells and intensive enough different from without acidity control group. Especially, the compounds have unique fluorescence in acidic environment and has great potential and research value as acidic probes.Exosomes are regarded as a promising biomarker in the diagnosis of disease due to their close relationship with the change of physiology and pathology. However, it is still a hard challenge to come up with a highly sensitive method for the exosomes detection. Herein, we propose a spherical nucleic acids (SNAs)-based cascade signal amplification strategy for the exosomes detection with high sensitivity. In this method, SNAs anchoring on exosomes membrane can be extended to form polyT sequence by terminal deoxynucleotidyl transferase (TdT), generating a template strand for the Exo III-catalyzed excision of the designed signal probe (probe A), which may finally induce significant decrease of electrochemical signal due to the consumption of probe A. Benefiting from the SNAs-based cascade signal amplification, this fabricated biosensor achieves a limit of detection for exosomes as low as 44 particles/μL. Moreover, this method shows good performance in the differentiation of healthy and malignancy colorectal cancer patients. Therefore, without complicated nucleic acids sequences design, our approach provides a cascade signal amplification strategy for the highly sensitive detection of exosomes and shows the potential applications in clinical diagnosis.The conventional skin sensor detection of human physiological signals can be an effective method for disease diagnosis and health monitoring, but the poor biocompatibility, low sensitivity and complex design largely limit their applications. Developing natural nanofiller-reinforced composites as strain biosensors is an appealing solution to reduce environmental impacts and overcome technical bottleneck. Herein, a versatile nature skin-inspired composite film as flexible strain biosensor was developed based on cellulose nanocrystals-polyaniline (CNC-PANI) composites by utilizing their percolated conductive network in polyvinyl alcohol (PVA) matrix. The composite electronic skin showed robust mechanical strength (50.62 MPa) and high sensitivity (Gauge Factor = 11.467) with easy water-induced self-healing abilities. Moreover, we investigated the functioning mechanism of percolated network and the sensory behavior determined by CNC nanocomposite alignment. The percolation threshold of CNC-polyaniline (PANI) was determined at 4.278% and 5% CNC-PANI composite film shows the best overall sensing property. It was also discovered that the sensitivity of this type of conductive-filler electronic skin can be divided into two separate regions at different strain range due to its percolated network. With films prepared by dry casting and dip coating, the alignment of CNC-PANI also contributes to this unique change in electrical property. Generally, our results demonstrated the mechanism and tunability of conductive nanofiller-based composite strain biosensors as a potential alternative to commercial synthetic sensors.

riddlekitten44's listings

User has no active listings
Start selling your products faster and free Create Acount With Ease
Non-logged user
Hello wave
Welcome! Sign in or register