About seller
can be addressed in a staged procedure. Our results have been satisfactory and add to the scant literature available on the subject, however further studies are warranted. Scapular fractures are uncommon injuries of upper extremity resulting mostly from high-energy trauma. Extra-articular fractures form the majority of them. Un-displaced fractures can be managed conservatively with good results. But displaced fracture does not yield satisfactory results and needs surgical fixation. In this case series, we report our experience about such fractures. This was a retrospective study of 12 patients with displaced scapular body and neck fractures treated between 2015 and 2018. Scapular fractures were exposed by modified Judet approach and fixed with either 3.5mm T buttress or recon locking plate and screws. One case had associated clavicle fracture which was fixed along with scapula. Patients were put on structured rehabilitation and followed up regularly. Functional outcome and range of motion were analyzed. The patients included 10 males and two females. Mean age was 42years. Average follow-up was 33months. Average constant and Murley score was 80. Excellent results were seen in four patients, good results in seven patients and one patient has got fair result. The mean post-operative range of motion of the shoulder at the time of final follow-up was 140° of forward flexion, 136° of abduction, and 34° of external rotation. Displaced extra-articular scapular fractures managed by internal fixation using T buttress locking plates and reconstruction plates give good functional outcome.Displaced extra-articular scapular fractures managed by internal fixation using T buttress locking plates and reconstruction plates give good functional outcome. Fractures of the proximal humerus represent approximately 4% of all fractures and 26% of humerus fractures. Proper reduction, stable internal fixation and early initiation of physiotherapy help to achieve a good functional outcome. Aim of this study was to evaluate varus fixation/malunion of proximal humerus fractures and its relation to functional outcome. We retrospectively evaluated 32 patients with proximal humerus fractures who were surgically treated between 2015 and 2017 at tertiary care hospital. We divided the patients into three groups on the basis of the neck-shaft angle as valgus group, normal group and varus group to observe the influence of neck-shaft angle on efficacy. Patients were evaluated for functional outcome using the Constant-Murley score. Two-part fractures had better functional outcome (Constant score = 75.15) compared to three parts with the moderate functional outcome (Constant score = 68.81) and the four-part fracture had poor functional outcome (Constant score = 52.66). After 6months of follow-up, 13 patients had a neck-shaft angle of less than 126°. The functional outcome is significantly better among patients with normal neck-shaft angle and had a mean Constant score of 76.63 as compared to patients with varus deformity had a mean Constant score 60 ( = 0.001). 10 patients did not have medial support, in which 08 patients had neck-shaft angle less than 126° and 2 had a normal neck-shaft angle. High fracture comminution, improper restoration of medial continuity causes varus deformity of the humeral head and it leads to poor functional outcome. The small sample size is the limitation of our study.High fracture comminution, improper restoration of medial continuity causes varus deformity of the humeral head and it leads to poor functional outcome. The small sample size is the limitation of our study. This retrospective study was conducted to evaluate the efficacy of dual locking plate osteosynthesis for treating 3- or 4-part proximal humeral fractures combined with multiple fractures of the greater tuberosity. From January 2012 to December 2018, 19 skeletally mature patients, who suffered 3- or 4-part proximal humeral fractures combined with multiple fractures of the greater tuberosity, were treated with open reduction and internal fixation using a dual locking plate technique through a delto-pectoral approach. Indexes for evaluation included fracture healing, quality of reduction, and incidence of complications (infections, screw perforation into the glenohumeral joint, subacromial impingement, hardware failure, avascular necrosis, and loss of reduction). Shoulder function was evaluated using Constant-Murley scoring. The patients were assessed at a mean time of 25.3months after surgery. Union of fractures was radiographically confirmed for all 19 patients. The mean Constant-Murley patient score was 85.2 points, and complications were identified in two patients during follow-up evaluations. The method of using dual locking plate osteosynthesis through a delto-pectoral approach resulted in a satisfactory union rate, excellent fracture reduction, low complication rate and good shoulder function for patients with complex proximal humeral fractures. KU-0063794 in vitro The method is effective for treating 3- or 4-part proximal humeral fractures combined with multiple fractures of the greater tuberosity.The method of using dual locking plate osteosynthesis through a delto-pectoral approach resulted in a satisfactory union rate, excellent fracture reduction, low complication rate and good shoulder function for patients with complex proximal humeral fractures. The method is effective for treating 3- or 4-part proximal humeral fractures combined with multiple fractures of the greater tuberosity. The coexistence of supracondylar humerus fracture and forearm fracture is a rare trauma (3-13%) and it is called floating elbow. The aim of this study is to clinically compare the treatment outcomes of the patients diagnosed with floating elbow who underwent surgical treatment and who were followed up forearm with immobilization with splint. When scanned retrospectively, 60 patients who were treated with the diagnosis of floating elbow due to traumatic causes and followed up for at least 1year were included in our study. Surgical treatment was performed on 42 patients for forearm fracture. Eighteen patients followed up with immobilization with a long arm splint. The results were evaluated according to the criteria modified by Templeton and Graham, in comparison with the patient's intact side. In the patients whose forearms were followed up conservatively, the mean age was 5.67 ± 2.25years, and the mean follow-up period was 62.17 ± 45.91months. In the patients who underwent surgery for the forearm, the mean age was 8.