About seller
A wearable textile brace is introduced as an electromagnetic imaging system that breaks hospital boundaries to real-time onsite scanning for knee injuries. The proposed brace consists of a 12-element textile slot loop antenna array, which is designed to match the human knee for enhanced electromagnetic wave penetration. Wool felt and conductive fabric are used to fabricate the antenna array thanks to their flexibility and proper dielectric properties. Each antenna element has a compact footprint of. and achieves unidirectional radiation, high front-to-back ratio of 14 dB, wide bandwidth of 81% at 0.7-1.7 GHz, and safe SAR levels. A modified double-stage delay, multiply, and sum (DS-DMAS) algorithm is used to process the collected signals from the antenna array based on differential left/right knee imaging. The reconstructed images numerically and experimentally on realistic phantoms demonstrate the potential of the brace system for onsite detection of different types of ligaments/tendon tears.Over the past decades, Chemical-induced Disease (CID) relations have attracted extensive attention in biomedical community, reflecting wide applications in biomedical research and healthcare field. However, prior efforts fail to make full use of the interaction between local and global contexts in biomedical document, and the derived performance needs to be improved accordingly. In this paper, we propose a novel framework for document-level CID relation extraction. More specifically, a stacked Hypergraph Aggregation Neural Network (HANN) layers are introduced to model the complicated interaction between local and global contexts, based on which better contextualized representations are obtained for CID relation extraction. In addition, the CID Relation Heterogeneous Graph is constructed to capture the information with different granularities and improve further the performance of CID relation classification. Experiments on a real-world dataset demonstrate the effectiveness of the proposed framework.The heterogeneous nature of a cell population creates a lot of challenges in cancer study. Determining the compositional breakup of a cell population from gene expression measurements efficiently is critical in cancer study. This paper presents a new model for analyzing heterogeneity in cancer tissue using Markov chain Monte Carlo (MCMC) algorithms; we aim to compute the proportion wise breakup of the cell population on a GPU. We also show that the model computation time does not depend on the input data size, because the computation required to estimate the compositional breakup are parallelized. This model uses qPCR (quantitative polymerase chain reaction) gene expression data to determine compositional breakup in the heterogeneous cell population. We test this model on synthetic data and real-world data collected from fibroblasts. We also show how well this model scales to hundreds of gene expression data.Cable theory is used to model fibers (neural or muscular) subjected to an extracellular stimulus or activating function along the fiber (longitudinal stimulation). There are cases however, in which activation from fields across a fiber (transverse stimulation) is dominant and the activating function is insufficient to predict the relative stimulus thresholds for cells in a bundle. This work proposes a general method of quantifying transverse extracellular stimulation using ideal cases of long fibers oriented perpendicular to a uniform field (circular cells in a 2-D extracellular domain). Several methods are compared against a fully coupled model to compute electrical potentials around each cell of a bundle and predict the magnitude of applied plate potential (Öp) needed to activate a given cell (Öpact). The results show that with transverse stimulation, the effect of cell presence on the external field must be considered to accurately compute Öpact. They also show that approximating cells as holes can accurately predict firing order and Öpact of cells in bundles. Potential profiles from this hole model can also be applied to single cell models to account for time-dependent transmembrane voltage responses and more accurately predict Öpact. The approaches used herein apply to other examples of transverse cell stimulation where cable theory is inapplicable and coupled model simulation is too costly to compute.Remote monitoring of physical activity using bodyworn sensors provides an alternative to assessment of functional independence by subjective, paper-based questionnaires. This study investigated the classification accuracy of a combined surface electromyographic (sEMG) and accelerometer (ACC) sensor system for monitoring activities of daily living in patients with stroke. sEMG and ACC data were recorded from 10 hemi paretic patients while they carried out a sequence of 11 activities of daily living (Identification tasks), and 10 activities used to evaluate misclassification errors (non-Identification tasks). The sEMG and ACC sensor data were analyzed using a multilayered neural network and an adaptive neuro-fuzzy inference system to identify the minimal sensor configuration needed to accurately classify the identification tasks, with a minimal number of misclassifications from the non-Identification tasks. The results demonstrated that the highest sensitivity and specificity for the identification tasks was achieved using a subset of 4 ACC sensors and adjacent sEMG sensors located on both upper arms, one forearm, and one thigh, respectively. This configuration resulted in a mean sensitivity of 95.0 %, and a mean specificity of 99.7 % for the identification tasks, and a mean misclassification error of less then 10% for the non-Identification tasks. The findings support the feasibility of a hybrid sEMG and ACC wearable sensor system for automatic recognition of motor tasks used to assess functional independence in patients with stroke.Effective clinical trials for neuroprotective interventions for Parkinson's disease (PD) require a way to quantify an individual's motor symptoms and analyze the change in these symptoms over time. Clinical scales provide a global picture of function but cannot precisely measure specific aspects of motor control. We have used commercially available sensors to create a protocol called ASAP (Advanced Sensing for Assessment of Parkinson's disease) to obtain a quantitative and reliable measure of motor impairment in early to moderate PD. selleck chemicals The ASAP protocol measures grip force as an individual tracks a sinusoidal or pseudorandom target force under three conditions of increasing cognitive load. Thirty individuals with PD have completed the ASAP protocol. The ASAP data for 26 of these individuals were summarized in terms of 36 variables, and modified regression techniques were used to predict an individual's score on the Unified Parkinson Disease Rating Scale based on ASAP data. We observed a mean prediction error of approximately 3.