doctorpage47
doctorpage47
0 active listings
Last online 1 year ago
Registered for 1+ year
Aba South, Enugu, Nigeria
614344Show Number
Send message All seller items (0) www.selleckchem.com/products/r-hts-3.html
About seller
Single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) has become a well-established technique for the detection, size characterization and quantification of inorganic nanoparticles but its use for the analysis of micro- and nanoparticles composed of carbon has been scarce. Here, the analysis of a microplastic suspensions by ICP-MS operated in single particle mode using microsecond dwell times is comprehensively discussed. The detection of polystyrene microparticles down to 1.2 μm was achieved by monitoring the 13C isotope. Plastic microparticles of up to 5 μm were completely volatized and their components atomized, which allowed the detection of microplastics, their quantification using aqueous dissolved carbon standards, and the measurement of the size-distribution of the detected particles. Limits of detection of 100 particles per milliliter were achieved for an acquisition time of 5 min. The method developed was applied to the screening of microplastics in personal care products and released from food packagings. The chemical identity of the detected microplastics was confirmed by attenuated total reflectance Fourier-transform infrared spectroscopy.Preconcentration of Cd(II), Co(II), Cu(II), Ni(II), Pb(II), and Zn(II) in aqueous biphasic system tetrabutylammonium bromide (TBAB) - H2O - (NH4)2SO4 followed by ICP-OES determination is reported for the first time. All metal ions extracted quantitatively with 4-(2-pyridylazo)-resorcinol. Nonwoven polypropylene collector was used to capture the extract and to assist phase separation. The concentrate was eluted with 0.3 mol L-1 nitric acid and introduced directly into ICP-OES sampling line. Detection limits for cadmium, cobalt, copper, nickel, lead, and zinc were 0.012, 0.2, 0.17, 0.11, 0.2, and 0.4 μg L-1, respectively; preconcentration factor was 150. The method accuracy was verified by the analysis of certified reference materials samples of waste waters and surface water, as well as the real samples of spring and well water. The use of oleophilic polypropylene collector allowed to handle small volume extract, attain high preconcentration factor and significantly decrease detection limits for ICP-OES determination of heavy metals.Surface plasmon resonance (SPR) has been widely used to detect a variety of biomolecular systems, but only a small fraction of applications report on the analysis of patients' samples. Selleck GLXC-25878 A critical barrier to the full implementation of SPR technology in molecular diagnostics currently exists for its potential application to analyze blood plasma or serum samples. Such capability is mostly hindered by the non-specific adsorption of interfering species present in the biological sample at the functional interface of the biosensor, often referred to as fouling. Suitable polymeric layers having a thickness ranging from 15 and about 70 nm are usually deposited on the active surface of biosensors to introduce antifouling properties. A similar approach is not fully adequate for SPR detection where the exponential decay of the evanescent plasmonic field limits the thickness of the layer beyond the SPR metallic sensor surface for which a sensitive detection can be obtained. Here, a triethylene glycol (PEG(3))-pentrimer carboxybetaine system is proposed to fabricate a new surface coating bearing excellent antifouling properties with a thickness of less than 2 nm, thus compatible with sensitive SPR detection. The high variability of experimental conditions described in the literature for the quantitative assessment of the antifouling performances of surface layers moved us to compare the superior antifouling capacity of the new pentrimeric system with that of 4-aminophenylphosphorylcholine, PEG-carboxybetaine and sulfobetaine-modified surface layers, respectively, using undiluted and diluted pooled human plasma samples. The use of the new coating for the immunologic SPRI biosensing of human arginase 1 in plasma is also presented.Membrane filters were coated with 10,12-pentacosadiynoic acid (PCDA) then polymerized on the filter for rapid bacterial detection and quantification. The polymerized PCDA (pPDCA)-coated filter changed color in response to Salmonella Typhimurium and Escherichia coli but not to Listeria innocua. The time required for color change of pPCDA-coated filters was determined by a visual panel. A simple linear regression model was generated to fit the observed data and was validated with goodness of fit analysis and residual analysis. The pPCDA-filter method estimated Salmonella Typhimurium populations of 8 to 3 log CFU ml-1 within 1.5-7.5 h, respectively.Liquid-liquid extraction (LLE) and stir bar sorptive extraction (SBSE) are extraction methods used for the analysis of contaminants in aqueous samples. In this study, both LLE and SBSE were compared for the extraction of priority pollutants and contaminants of emerging concern (CECs) in wastewater influent and effluent samples, for analysis with comprehensive two-dimensional gas chromatography with time of flight mass spectrometry (GC × GC-TOFMS). The methods were compared for their extraction efficiency of a broad range of compounds, matrix effects, accurate and reliable quantification of targets, and sensitivity. The target analytes studied were semi-volatile organic compounds (SVOC) including polycyclic aromatic hydrocarbons, phenols, phthalate esters, anilines, ethers, aromatic nitro compounds, and nitrosamines. LLE allowed for a higher number of target analytes to be extracted with over 70% recovery and quantified more targets in the influent samples. Matrix interference effects had a negative impact on the recovery of non-polar contaminants, such as polycyclic aromatic hydrocarbons (PAHs), in the influent water samples especially with SBSE. In SBSE, 24 target analytes demonstrated significant matrix interference leading to poor analyte recovery and 13 analytes were negatively affected in the same way in LLE. Generally, polar compounds also demonstrated poor extraction with SBSE in both effluent and influent water samples. However, SBSE effluent chromatograms contained about three times as many total analytes as compared with LLE, suggesting that SBSE is more sensitive for trace contaminants in effluent samples. Based on this research, LLE is recommended for studies seeking to quantify a broad range of target analytes in complex matrices, like wastewater influent. SBSE is an appropriate method for the non-target and survey analysis of trace contaminants in less complex water samples.

doctorpage47's listings

User has no active listings
Start selling your products faster and free Create Acount With Ease
Non-logged user
Hello wave
Welcome! Sign in or register