About seller
52 ± 22.37 ms, including trials involving multiple speed transitions. This would enable development of a compact wearable system for robust gait analysis in real-world settings, providing key insights into gait quality with the capability for real-time system control.This paper proposes a detection method of fetal breathing movement (FBM) as an important data of fetal well-being. To analyze the chaotic nature of the individual episodes, the frequency band has been split into single test frequencies in order to find its starting point (SP) as a signal free (quiet) zone. Computing some features of the signal the sound will be distinguishable from the disturbing signals as hiccups, body's rotation and limb movements or even additional noises of maternal heart beats. The SPs of the episodes are characterized by an approximation process in order to select the real ones.Clinical relevance- The method is an irradiation free measurement, carried out on the maternal abdomen. Furthermore, connected with the fetal phonocardiographic (fPCG) monitoring the method offers a non-invasive way for FBM detection applicable also at home. More than 50 pregnancies were examined with the proposed method for at least for 20-min with synchronous measurements by the proposed phonographic device and a 3D ultrasound machine in the third trimester.Motion artifacts are arguably the most important issue in the development of wearable ambulatory EEG devices. Designing circuits and systems capable of high-quality EEG recording regardless of these artifacts requires a clear understanding of how the electrode-skin interface is affected by physical motions. In this work, first, we report statistically-significant experimental characterization results of electrodeskin interface impedance for dry contact and non-contact electrodes in the presence of various motions. This leads to a model describing the motion-induced electrode-skin interface impedance variations for these electrodes. Next, a critical review of the possible analog front-end circuits for surface EEG recording is presented, followed by theoretical circuit analysis discussing the effect of electrode movements on the operation of these circuits. Inspired by the developed model and the analytical review, a novel front-end architecture capable of extracting motion from the EEG signal during the amplification stage is presented and experimentally characterized.This study concerns a measurement device and an algorithm of the laryngeal elevation for the Mendelsohn maneuver. The measurement device is band-shaped and measures the change of the circumferential length of the neck by stretchable strain sensors. The device is lightweight of 35 g. The algorithm detects the onset and offset points in time of the laryngeal elevation by the first-order difference and the dynamic time warping distance. Twelve elderly people participated in an experiment to validate the effectiveness of the device. A clustering method separated the measurement data into two groups based on their waveforms. We defined template data from the measurement data. LPS The algorithm detected the onset and offset time by using the template data. Although the offset time of a group had an error of about 4 s, the onset and offset time points of the other group were errors within 1 s.We present an enhanced R-peak detection technique that incorporates both waveform shape recognition and threshold sensitivity enhancement. Waveform shape recognition was achieved with signal processing and Gaussian curve parameterization; threshold sensitivity was accomplished with the famous Pan-Tompkins algorithm. We tested all 48 records in MIT-BIH Arrhythmia Database to validate the proposed method. Our method achieved 97.41% sensitivity against a tolerance window of 10% averaged R-R interval, which improves the current state-of-the-art Pan-Tompkins algorithm by 1%. More importantly, we demonstrate that our approach outperforms the Pan-Tompkins' algorithm in 81% of the records in MIT-BIH Arrhythmia Database.Clinical relevance High sensitivity R-peak detection is substantial in various cardiovascular disease diagnosis.The efficacy of implantable medical devices is limited by the longevity of devices in the body environment. Due to the aqueous and mobile-ion rich environment of tissue, robust and long-lasting encapsulation materials are critical for chronic implants. Assessing the reliability of medical devices is commonly performed through saline soak tests with reactive oxidative species at elevated temperatures and lifetime data are fit to an Arrhenius model to predict lifetime under physiological conditions. While effective, these systems often require frequent human involvement to maintain system temperature and reactive oxidative species concentration, as well as monitor sample lifetime, which makes long term testing of multiple samples difficult. Here we present an automated, low-cost, low-solution volume, and high-throughput reactive accelerated aging system to assay many thin film samples in an easy and low maintenance manner. The efficacy of up to 16 thin film coating samples can be assessed by our system through in-situ current leakage tests in a mock biological environment. We validate our system by aging thermal oxide and a-SiC thin films at 93 °C with 20 mM H2O2. Our system shows early failure of the thermal oxide compared to the a-SiC, in agreement with the current literature.In the here-reported study, we investigated the dielectric properties of three different skin-mimicking materials used in the reported controlled experiments for development and testing of microwave-range medical devices. Each of the phantom materials under consideration is tested in two forms a thicker, larger block and a 2-mm sheet. The measured properties are compared to a reference of human skin tissue measurements from literature. Depending on the frequency range of the medical device in development, some phantoms are more suitable to represent human skin than others. We observe that all phantoms still show lower dielectric properties than the human skin reference, but are suitable representations of skin at microwave applications if used as 2-mm thin layers.